Dell powervault 132t driver




















The Quantum diag utility tests both drives as good. So as you can see I'm running to the end of my resourcefullness. If anyone has an idea I'd be happy to entertain it. Normally, when you run a backup job, a data verification check will be run once the backup is complete.

If you check your Backup Exec job logs, it will tell you if the verify phase failed. RSM can interfere with the library. If you have two drives in the T, only run one backup job to one drive.

Need to find out if the problem is happening on one or both drives. As a last resort, you may want to disconnect one of the drives from the SCSI bus. Want to see if one of the drives is causing SCSI bus interference with the other drives. Before getting in the replacement parts, the CRC errors were happening consistently at the 1 hour 20 min. Since replacement one of the backup jobs did fail during the Verify portion but after there was a log entry stating that it had succeeded to verify.

So after I changed it to do both I did not get the same error for that particular backup and it ran successfully, but when the next backup tried to start, even though the tape was already inside of the right drive, it failed with the "Robotic Library Hardware Error" which took the entire library offline.

I had to eject the tape manually. Here are the answers to the rest of your questions, thanks for your help! All backup jobs point to the one drive that is failing.

I have already "swapped" drives with the same problem. The local computer may not have the necessary registry information or message DLL files to display messages from a remote computer. That's the one thing I hadn't checked today.

Do you think I might need to reload the drivers for the adapter or replace the adapter I have a new identical adapter I can use? It seems that you are also having hardware problems, espeicially if your "move" tests are producing picker failures.

Also, when the event viewer reports that the "tape device is not ready for access", this means that the OS has lost communication with the tape device tape1 , which is your second tape drive. Once this occurs, the OS will normally remove the device from the device manager. If you run a device rescan from the OS device manager, the device may re-appear, otherwise you need to reboot the server. Make sure that the robot appears during server POST.

If it does not appear during POST, check cabling, termination or library settings. I'm attempting to use Brightstor Arcserver software with it, as it recognizes it's a dell, but doens't let me load it as a library, just a drive. You have to install the Changer Software sep purchase then the base backup software. Check the patches area for upgrades to allow you to see more devices. Both of those things got my PVT working. I had the library set to sequential, It should have been random.

After restarting the server, the scsi card saw the robot. Browse Community. Turn on suggestions. Auto-suggest helps you quickly narrow down your search results by suggesting possible matches as you type. Showing results for. Search instead for. Did you mean:. So, we are at a finger pointing stage. It would be greatly appreciated. Go to Solution. View solution in original post. Also check if this PVT is configured without any advanced features like partitioning, with latest firmware.

Please ensure that you have to restart Media Manager or whole NetBackup after tape device configuration changes. The tape drive was indeed in sequential mode, with partitioning turned on. Communities View more. Turn on suggestions. Auto-suggest helps you quickly narrow down your search results by suggesting possible matches as you type.

Showing results for. Search instead for. Did you mean:. Sign In. Issue with tape drive - Dell Powervault T - windows server master. Go to solution. I have tried: Removing the tape drives from the device manager, rescanning for changes, etc.